Peptides
rHGH fragment or AOD-9604 (LCMS+CHNS) analysis
Adds mass-spec identification and net peptide content by elemental analysis.
Full details are in the parameters section below.
Mass spectrometry confirms the identity of the fragment rather than inferring it from a retention time — worth having, because the fragment is sold in several variants that a UV detector cannot tell apart.
CHNS elemental analysis then separates net peptide from counter-ion salt and residual water. That gap is the usual reason a vial weighs what the label says while containing considerably less peptide.
What you send in
Min. 5 mg powder
What the report contains
- Compound identified
- Net peptide content
- Salt and water fraction
- Mass spectrum
| Parameter | Value |
|---|---|
| Testing method | LC-MS + CHNS elemental analysis |
| Result format | Compound identified |
| Minimum sample amount | Min. 5 mg powder |
| Average turnaround time | 7-10 business days |
€306.00
After checkout you receive a test ID and the shipping instructions. The turnaround time starts once your sample arrives at the lab.